SEPS_a283 — Position Detect Failed
Full alert identifier: SEPS_a283_positionDetectFailed
Alert description
Steering rack position detection algorithm is unable to run. Rack position is not resolved. Alert log signal data should provide more information on specific condition(s) involved.
Potential impact
Rack control not possible.
Set condition
Position detection preconditions not achieved or lost during detection.
Clear condition
Position detection starts again. A DRIVE or CONDITIONING cycle is necessary to retry.
Signals to check
These diagnostic fields are associated with SEPS_a283. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Local Rack Force
SEPS_
|
N |
Main Angle Quality
SEPS_
|
— |
Preload Good
SEPS_
|
— |
Rack Speed
SEPS_
|
m/s |
Remote Rack Force
SEPS_
|
N |
Solver Ready
SEPS_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of SEPS_a283.