Skip to content

SEPS_a209 — Startup Sequence Failed

Full alert identifier: SEPS_a209_startupSequenceFailed

Alert description

Power steering startup sequence is unsuccessful.

Potential impact

The motor is disqualified and system health is degraded.

Set condition

Controller calibration check is unsuccessful, corresponding controller monitor is not responding, or state timeout occurs.

Clear condition

Startup sequence passes. Startup sequence is run during vehicle startup, and the condition may resolve by drive cycling the vehicle.

Signals to check

These diagnostic fields are associated with SEPS_a209. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Failed State SEPS_a209_failedState —
Gate Driver Internal State SEPS_a209_gateDriverInternalState —
Monitor Startup Failed SEPS_a209_monitorStartupFailed —
State Timeout Exceeded SEPS_a209_stateTimeoutExceeded —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of SEPS_a209.

Browse all SEPS alert codes