Skip to content

SEPSM_a146 — TMR Angle Sensor Value Invalid

Full alert identifier: SEPSM_a146_TMRAngleSensorValueInvalid

Alert description

Motor angle sensor has been deemed invalid.

Potential impact

The motor is disqualified and rack control health is degraded.

Set condition

The motor angle sensor signals do not pass the Pythagorean identity rationality check.

Clear condition

The motor angle sensor signals return to rational bounds.

Signals to check

These diagnostic fields are associated with SEPSM_a146. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Pythagorian Identity Error SEPSM_a146_pythagorianIdentityError —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of SEPSM_a146.

Browse all SEPSM alert codes