Skip to content

SDCR_a025 — Di Switching Fdbk Irrational

Full alert identifier: SDCR_a025_diSwitchingFdbkIrrational

Alert description

Drive inverter (DI) switching-feedback (fdbk) pin to secondary disconnect controller (SDC) is in an irrational state.

Potential impact

Pyro disconnect may not function as expected.

Set condition

DI switching-feedback pin is set but DI running-feedback is cleared.

Clear condition

DI switching-feedback pin is cleared.

Signals to check

These diagnostic fields are associated with SDCR_a025. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
HV Backup Supply V SDCR_a025_HVBackupSupplyV V
Boost Rail V SDCR_a025_boostRailV V
Di Switching From Uart SDCR_a025_diSwitchingFromUart —
Di Switching Pin SDCR_a025_diSwitchingPin —
Di Uart MIA SDCR_a025_diUartMIA —
Pm Running Pin SDCR_a025_pmRunningPin —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of SDCR_a025.

Browse all SDCR alert codes