Skip to content

SDCR_a004 — Pm Running Fdbk Irrational

Full alert identifier: SDCR_a004_pmRunningFdbkIrrational

Alert description

Drive inverter (DI) running-feedback (fdbk) pin to secondary disconnect controller (SDC) is in an irrational state.

Potential impact

SDC will not skip pyro self-test (PST) if DI is MIA at startup. Potential overlapping pyro self-tests.

Set condition

DI UART data is active, but running-feedback pin state is low.

Clear condition

DI running-feedback pin is set, or universal asynchronous receiver-transmitter (UART) communication stops.

Signals to check

These diagnostic fields are associated with SDCR_a004. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
HV Backup Supply V SDCR_a004_HVBackupSupplyV V
Boost Rail V SDCR_a004_boostRailV V
Di Present SDCR_a004_diPresent —
Pm Running Pin SDCR_a004_pmRunningPin —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of SDCR_a004.

Browse all SDCR alert codes