Skip to content

SDCR_a020 — Eeprom SPI Error

Full alert identifier: SDCR_a020_eepromSPIError

Alert description

The external electrically erasable programmable read-only memory (EEPROM) is returning unexpected data over the serial peripheral interface (SPI).

Potential impact

Analysis of trigger condition for a previous pyro disconnect event cannot be completed because EEPROM data is inaccessible.

Set condition

Invalid data received from external EEPROM over SPI.

Clear condition

Correct, valid data is received from the external EEPROM.

Signals to check

These diagnostic fields are associated with SDCR_a020. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Error Code SDCR_a020_errorCode
1
ADDRESS OUT OF BOUNDS
2
PAGE ROLLOVER
3
MUTEX ERROR
4
GENERIC SPI ERROR
200
FAILED READ SANITY CHECK
201
FAILED WRITE SANITY CHECK
—
Rx Data 0 SDCR_a020_rxData0 —
Rx Data 1 SDCR_a020_rxData1 —
Rx Data 2 SDCR_a020_rxData2 —
Rx Data 3 SDCR_a020_rxData3 —
Rx Data 4 SDCR_a020_rxData4 —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of SDCR_a020.

Browse all SDCR alert codes