Skip to content

SDCR_a017 — Adc SPI Error

Full alert identifier: SDCR_a017_adcSPIError

Alert description

The external analog to digital converter (ADC) is returning invalid data over the serial peripheral interface (SPI).

Potential impact

Phase voltage sensing data is incorrect, which may affect pyro disconnect functionality.

Set condition

Invalid data is received from the external ADC over SPI.

Clear condition

Correct, valid data is received from the external ADC.

Signals to check

These diagnostic fields are associated with SDCR_a017. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Expected Config Word SDCR_a017_expectedConfigWord —
Received Config Word SDCR_a017_receivedConfigWord —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of SDCR_a017.

Browse all SDCR alert codes