SDCR_a019 — Historical Fault Currents
Full alert identifier: SDCR_a019_historicalFaultCurrents
Alert description
Secondary disconnect controller (SDC) detected abnormal electrical currents during a previous power-ON state. Data retrieved from electrically erasable programmable read-only memory (EEPROM).
Potential impact
Drive unit may not be functional due to previous electrical issue.
Set condition
SDC detected abnormal electrical currents when drive inverter (DI) was not switching as expected during a previous power cycle.
Clear condition
SDC completes successful power-ON self-test.
Signals to check
These diagnostic fields are associated with SDCR_a019. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Avg Ia
SDCR_
|
A |
Avg Ib
SDCR_
|
A |
Fault Reason Fault Currents At Speed
SDCR_
|
— |
Fault Reason Propagating 3 PS
SDCR_
|
— |
Fault Reason Unmitigated UCR
SDCR_
|
— |
Imbalance Seen
SDCR_
|
— |
Max Abs Currents
SDCR_
|
A |
Max Abs Elc Speed
SDCR_
|
Hz |
Show 5 more fields
| Signal | Unit |
|---|---|
Phase Voltage Present
SDCR_
|
— |
Speed From Voltage
SDCR_
|
— |
Speed Was Valid
SDCR_
|
— |
Transient Handling
SDCR_
|
— |
Ucr Seen
SDCR_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of SDCR_a019.