SDCR_a007 — Fault Currents Detected
Full alert identifier: SDCR_a007_faultCurrentsDetected
Alert description
Secondary disconnect controller (SDC) detected abnormal motor currents.
Potential impact
SDC may trigger the pyro disconnect.
Set condition
Detection of abnormal drive unit currents by the SDC when drive inverter (DI) is not switching.
Clear condition
Drive unit can control currents rationally, or SDC processor is reset.
Signals to check
These diagnostic fields are associated with SDCR_a007. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Avg Ia
SDCR_
|
A |
Avg Ib
SDCR_
|
A |
Fault Reason Fault Currents At Speed
SDCR_
|
— |
Fault Reason Propagating 3 PS
SDCR_
|
— |
Fault Reason Unmitigated UCR
SDCR_
|
— |
Imbalance Seen
SDCR_
|
— |
Max Abs Currents
SDCR_
|
A |
Max Abs Elc Speed
SDCR_
|
Hz |
Show 5 more fields
| Signal | Unit |
|---|---|
Phase Voltage Present
SDCR_
|
— |
Speed From Voltage
SDCR_
|
— |
Speed Was Valid
SDCR_
|
— |
Transient Handling
SDCR_
|
— |
Ucr Seen
SDCR_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of SDCR_a007.