Skip to content

PMR_a005 — Torque In Neutral Or Park

Full alert identifier: PMR_a005_torqueInNeutralOrPark

Alert description

Pedal Monitor Warning: Torque Detected in non-torque producing gear.

Potential impact

The safety monitor will inhibit torque and excess heat production for the remainder of the drive cycle.

Set condition

The safety monitor sets this condition torque production error is detected.

Clear condition

This alert will clear on the next drive cycle.

Signals to check

These diagnostic fields are associated with PMR_a005. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
I D Qmagnitude PMR_a005_iDQmagnitude A
Torque Measured PMR_a005_torqueMeasured
-4096
SNA
Nm
Torque Reason PMR_a005_torqueReason
0
TORQUE IN NEUTRAL
1
CURRENT IN NEUTRAL
2
SLAVE ENABLE IN NEUTRAL
—

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PMR_a005.

Browse all PMR alert codes