PMR_a006 — Under Torque Check
Full alert identifier: PMR_a006_underTorqueCheck
Alert description
Pedal Monitor Warning: DI torque actual does not match PM torque measured
Potential impact
No immediate impact.
Set condition
Set when absolute difference between DIx_torqueActual and PMx_torqueMeasured is > 100Nm for 100ms
Clear condition
This alert will clear 1s after torque difference is below threshold
Signals to check
These diagnostic fields are associated with PMR_a006. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Motor RPM
PMR_
|
RPM |
Torque Actual
PMR_
|
Nm |
Torque Measured
PMR_
|
Nm |
Check other alerts