PMRER_a055 — Resolver
Full alert identifier: PMRER_a055_resolver
Alert description
Pedal Monitor Warning: Resolver operation abnormal.
Potential impact
The safety monitor will inhibit torque and excess heat production for the remainder of the drive cycle.
Set condition
The safety monitor sets this condition when resolver speed or angle measurements in correspondence with DI are considered irrational or out of bounds.
Clear condition
This alert will clear on the next drive cycle.
Signals to check
These diagnostic fields are associated with PMRER_a055. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Cla MIA
PMRER_
|
— |
Common Gain
PMRER_
|
1 |
Di Elec Angle Mismatch
PMRER_
|
— |
Di Elec Angle Mismatch Warn
PMRER_
|
— |
Di MIA
PMRER_
|
— |
Di Speed Mismatch
PMRER_
|
— |
Motor RPM
PMRER_
|
RPM |
No Carrier
PMRER_
|
— |
Show 3 more fields
| Signal | Unit |
|---|---|
Not Ready
PMRER_
|
— |
Phase Angle
PMRER_
|
1 |
Phase Out Of Spec
PMRER_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PMRER_a055.