Skip to content

PMRER_a004 — Excessive Decel Torque

Full alert identifier: PMRER_a004_excessiveDecelTorque

Alert description

Pedal Monitor Warning: Deceleration Torque.

Potential impact

The safety monitor will inhibit torque and excess heat production for the remainder of the drive cycle.

Set condition

The safety monitor sets this condition torque production error is detected.

Clear condition

This alert will clear on the next drive cycle.

Signals to check

These diagnostic fields are associated with PMRER_a004. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Torque Average PMRER_a004_torqueAverage —
Torque Decel Average PMRER_a004_torqueDecelAverage
-4096
SNA
Nm
Torque Decel Window PMRER_a004_torqueDecelWindow
-4096
SNA
Nm
Torque Measured PMRER_a004_torqueMeasured
-4096
SNA
Nm
Torque Window PMRER_a004_torqueWindow —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PMRER_a004.

Browse all PMRER alert codes