Skip to content

PMRER_a064 — Torque Intervention

Full alert identifier: PMRER_a064_torqueIntervention

Alert description

Pedal Monitor Warning: Torque Intervention.

Potential impact

The safety monitor will inhibit torque and excess heat production for the remainder of the drive cycle.

Set condition

The safety monitor sets this condition and indicates diagnostic information in its payload for root cause analysis.

Clear condition

This alert will clear on the next drive cycle.

Signals to check

These diagnostic fields are associated with PMRER_a064. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
UI Stopping Mode PMRER_a064_UI_stoppingMode
0
STANDARD
1
CREEP
2
HOLD
—
Di Crs State PMRER_a064_diCrsState
0
UNAVAILABLE
1
STANDBY
2
ENABLED
3
STANDSTILL
4
OVERRIDE
5
FAULT
6
PRE FAULT
7
PRE CANCEL
—
Intervention Type PMRER_a064_interventionType —
Pm Crs State PMRER_a064_pmCrsState
0
UNAVAILABLE
1
STANDBY
2
ENABLED
3
STANDSTILL
4
OVERRIDE
5
FAULT
6
PRE FAULT
7
PRE CANCEL
—
Short Detected By DI PMRER_a064_shortDetectedByDI —
Torque Cmd State PMRER_a064_torqueCmdState
0
SNA
6
Valid
8
Invalid
—

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PMRER_a064.

Browse all PMRER alert codes