Skip to content

PMREL_a011 — Phase Current Irrational

Full alert identifier: PMREL_a011_phaseCurrentIrrational

Alert description

Pedal Monitor Warning: Phase Current Irrational.

Potential impact

The safety monitor will initiate a unit limp condition for the remainder of the drive cycle.

Set condition

The safety monitor sets this condition when phase current sensor measurements are irrational or out of bounds.

Clear condition

This alert will clear when phase current sensor measurements are considered rational.

Signals to check

These diagnostic fields are associated with PMREL_a011. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Ia PMREL_a011_Ia A
Ib PMREL_a011_Ib A
Bad Phase Asample PMREL_a011_badPhaseAsample —
Bad Phase Bsample PMREL_a011_badPhaseBsample —
Current Vref PMREL_a011_currentVref V
Sample Freeze PMREL_a011_sampleFreeze —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PMREL_a011.

Browse all PMREL alert codes