Skip to content

PMREL_a026 — Di Heart Beat MIA

Full alert identifier: PMREL_a026_diHeartBeatMIA

Alert description

Pedal Monitor Warning: DI Heartbeat is missing.

Potential impact

The safety monitor will initiate a unit limp condition for the remainder of the drive cycle.

Set condition

The safety monitor sets this condition when DI Heartbeat communication is too fast or too slow.

Clear condition

This alert will clear when DI Heartbeat communication are considered rational.

Signals to check

These diagnostic fields are associated with PMREL_a026. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Control Stack Ovf PMREL_a026_controlStackOvf —
Eep Stack Ovf PMREL_a026_eepStackOvf —
Idle Stack Ovf PMREL_a026_idleStackOvf —
Imm Stack Ovf PMREL_a026_immStackOvf —
Isr Count 1 K Hz PMREL_a026_isrCount1kHz —
Isr Count 20 K Hz PMREL_a026_isrCount20kHz —
Reason PMREL_a026_reason
0
TooSlow
1
TooFast
—
Switching Active PMREL_a026_switchingActive —
Show 3 more fields
Signal Unit
System Stack Ovf PMREL_a026_systemStackOvf —
Xdc Error Arg 1 PMREL_a026_xdcErrorArg1 —
Xdc Error Id MSW PMREL_a026_xdcErrorIdMSW —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PMREL_a026.

Browse all PMREL alert codes