PEPS_a297 — Rack Preload Abort

Full alert identifier: PEPS_a297_rackPreloadAbort

Alert description

The rack moved unexpectedly during preload for calibration or position detection

Potential impact

Calibration or position detection cannot complete successfully.

Set condition

Rack sensors report rack movement of more than 0.5mm during a single preload cycle.

Clear condition

Cleared immediately.

Signals to check

These diagnostic fields are associated with PEPS_a297. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Displacement PEPS_a297_displacement m
Displacement Ok PEPS_a297_displacementOk —
Input Ok PEPS_a297_inputOk —
Local Force PEPS_a297_localForce N
Preload Status PEPS_a297_preloadStatus
0
IDLE
1
RUNNING KNOCK
2
RUNNING HOLD
3
RUNNING SQUARE
4
DONE KNOCK
5
DONE SQUARE
6
ABORT
7
UNKNOWN
—
Rack Mech State PEPS_a297_rackMechState —
Rack Speed PEPS_a297_rackSpeed m/s
Remote Force PEPS_a297_remoteForce N
Show 2 more fields
Signal Unit
Timeout Ok PEPS_a297_timeoutOk —
Torque Ok PEPS_a297_torqueOk —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PEPS_a297.