Skip to content

PEPS_a147 — Phase Disconnect Fault

Full alert identifier: PEPS_a147_phaseDisconnectFault

Alert description

The power steering motor phase disconnect signaled an error.

Potential impact

The motor is disqualified and rack control health is degraded.

Set condition

The phase disconnect detects an error condition (e.g. voltage out of range, communication issue, FET short).

Clear condition

The phase disconnect error condition must be cleared. A stable power supply is necessary. A DRIVE or CONDITIONING cycle is necessary for the error to be cleared.

Signals to check

These diagnostic fields are associated with PEPS_a147. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Bridge Driver Undervolt PEPS_a147_bridgeDriverUndervolt —
Charge Pump Undervolt PEPS_a147_chargePumpUndervolt —
Fault Reset PEPS_a147_faultReset —
Invalid Command PEPS_a147_invalidCommand —
Last Msg Not Ok PEPS_a147_lastMsgNotOk —
Neg Overcurrent PEPS_a147_negOvercurrent —
Neg Undervolt PEPS_a147_negUndervolt —
Overcurrent Timer PEPS_a147_overcurrentTimer —
Show 11 more fields
Signal Unit
Phase Disconnect Diag State PEPS_a147_phaseDisconnectDiagState —
Phase Disconnect MIA PEPS_a147_phaseDisconnectMIA —
Pos Overcurrent PEPS_a147_posOvercurrent —
Pos Undervolt PEPS_a147_posUndervolt —
Rev Batt Undervolt PEPS_a147_revBattUndervolt —
Spi Fault PEPS_a147_spiFault —
Temp Warning PEPS_a147_tempWarning —
U Phase Undervolt PEPS_a147_uPhaseUndervolt —
V Phase Undervolt PEPS_a147_vPhaseUndervolt —
W Phase Undervolt PEPS_a147_wPhaseUndervolt —
Watchdog Fault PEPS_a147_watchdogFault —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PEPS_a147.

Browse all PEPS alert codes