PCS2_a155 — Vcbattery Mia
Full alert identifier: PCS2_a155_vcbatteryMia
Alert description
PCS does not receive CAN messages from VC that manages the low voltage battery
Potential impact
DCDC functionality may be limited
Set condition
PCS does not receive all expected CAN messages from VC that manages the low voltage battery
Clear condition
PCS receives all expected CAN messages from VC that manages the low voltage battery
Signals to check
These diagnostic fields are associated with PCS2_a155. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
VC LV Health
PCS2_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PCS2_a155.