PCS2_a051 — Bms Mia
Full alert identifier: PCS2_a051_bmsMia
Alert description
The Power Conversion System (PCS) does not receive one or more Controller Area Network (CAN) messages from the Battery Management System (BMS)
Potential impact
DCDC, AC charging, and AC outlet functionality may be unavailable
Set condition
The PCS does not receive all expected CAN messages from the BMS
Clear condition
The PCS receives all expected CAN messages from the BMS
Signals to check
These diagnostic fields are associated with PCS2_a051. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
BMS Charge Status
PCS2_
|
— |
BMS Grid Form Control
PCS2_
|
— |
BMS Pack Config
PCS2_
|
— |
BMS Pcs Limits
PCS2_
|
— |
BMS Pcs Request
PCS2_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PCS2_a051.