PCS2_a075 — Hv Batt Full Sensor Irrational

Full alert identifier: PCS2_a075_hvBattFullSensorIrrational

Alert description

The high voltage (HV) battery full voltage measurement is irrational

Potential impact

DCDC, AC charging, and AC outlet functionality may be limited or paused

Set condition

The HV battery full voltage is irrationally high or low

Clear condition

The HV battery full voltage measurement comes back within a rational sensor range

Signals to check

These diagnostic fields are associated with PCS2_a075. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Hv Batt External Ref Value PCS2_a075_hvBattExternalRefValue
2047
SNA
V
Hv Batt Full Sensor Measurement PCS2_a075_hvBattFullSensorMeasurement V
Hv Batt Top Bottom Voltage Delta PCS2_a075_hvBattTopBottomVoltageDelta V

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PCS2_a075.

Browse all PCS2 alert codes