Alert description

The high voltage (HV) battery top voltage measurement is irrational

Potential impact

DCDC, AC charging, and AC outlet functionality may be limited or paused

Set condition

The HV battery top voltage is irrationally high or low

Clear condition

The HV battery top voltage measurement comes back within a rational sensor range

Signals to check

These diagnostic fields are associated with PCS2_a072. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Hv Batt External Ref Value PCS2_a072_hvBattExternalRefValue
2047
SNA
V
Hv Batt Top Sensor Measurement PCS2_a072_hvBattTopSensorMeasurement V

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PCS2_a072.