PCS2REXB_a110 — Ac Current Is Limited
Full alert identifier: PCS2REXB_a110_acCurrentIsLimited
Alert description
The Power Conversion System (PCS) AC operating current is limited
Potential impact
Limited AC current during AC charging or AC outlet operation
Set condition
The combined AC current derating factor is less than the limited current set threshold
Clear condition
The combined AC current derating factor is greater than the limited current clear threshold
Signals to check
These diagnostic fields are associated with PCS2REXB_a110. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Combined Derating Factor
PCS2REXB_
|
— |
Dc Temp Derating Factor
PCS2REXB_
|
— |
Derating Factor Threshold
PCS2REXB_
|
— |
Inductor Loss Derating Factor
PCS2REXB_
|
— |
Junction Temp Derating Factor
PCS2REXB_
|
— |
Tx Temp Derating Factor
PCS2REXB_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PCS2REXB_a110.