Skip to content

PCS2REXB_a010 — Ac LN Over Current

Full alert identifier: PCS2REXB_a010_acLNOverCurrent

Alert description

The AC Neutral current exceeds the allowed current threshold

Potential impact

AC charging and AC outlet functionality may be limited or paused

Set condition

The Neutral current exceeds the allowed current threshold

Clear condition

The DCAC system retries

Signals to check

These diagnostic fields are associated with PCS2REXB_a010. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Ac LN Over Current Trip PCS2REXB_a010_acLNOverCurrentTrip
0
COMPH TRIP
1
COMPL TRIP
—

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PCS2REXB_a010.

Browse all PCS2REXB alert codes