PCS2REXA_a119 — Use Max Cap For Hv Impedance Estimation
Full alert identifier: PCS2REXA_a119_useMaxCapForHvImpedanceEstimation
Alert description
The Power Conversion System (PCS) detects the initial high voltage (HV) bus voltage is too high to measure capacitance, so it must rely on the maximum possible capacitance value instead for HV bus impedance estimation.
Potential impact
PCS may underestimate the HV bus impedance.
Set condition
The initial HV bus voltage is too high to measure capacitance, so PCS must use maximum possible capacitance value to estimate HV bus impedance.
Clear condition
The DCDC converter is commanded to shut down or receives a new request to precharge the HV bus.
Signals to check
These diagnostic fields are associated with PCS2REXA_a119. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Present Hv Bus Voltage
PCS2REXA_
|
V |
Present Lv Bus Voltage
PCS2REXA_
|
V |
Start Up Hv Voltage
PCS2REXA_
|
V |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PCS2REXA_a119.