Skip to content

PCS2REXA_a042 — Hv Batt Over Voltage

Full alert identifier: PCS2REXA_a042_hvBattOverVoltage

Alert description

The high voltage (HV) battery goes above the allowed voltage threshold

Potential impact

DCDC functionality may be limited or paused

Set condition

The HV battery voltage goes above the allowed voltage threshold

Clear condition

The DCDC system retries

Signals to check

These diagnostic fields are associated with PCS2REXA_a042. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Hv Batt Bot Voltage PCS2REXA_a042_hvBattBotVoltage V
Hv Batt Top Voltage PCS2REXA_a042_hvBattTopVoltage V
Hv Batt Voltage PCS2REXA_a042_hvBattVoltage V
Voltage Fault Threshold PCS2REXA_a042_voltageFaultThreshold V

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PCS2REXA_a042.

Browse all PCS2REXA alert codes