Skip to content

PCS2REXA_a103 — Iso Temp Sensor Irrational

Full alert identifier: PCS2REXA_a103_IsoTempSensorIrrational

Alert description

An isolated temperature sensor measurement becomes irrational

Potential impact

DCDC, AC charging, and AC outlet functionality may be limited or paused

Set condition

An isolated temperature sensor measurement timing is beyond rational limits

Clear condition

An isolated temperature sensor measurement timing falls back within rational limits

Signals to check

These diagnostic fields are associated with PCS2REXA_a103. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Closed Loop Time PCS2REXA_a103_ClosedLoopTime nS
Fall Time Open Loop PCS2REXA_a103_FallTimeOpenLoop nS
Iso Temp Sense Irrational PCS2REXA_a103_IsoTempSenseIrrational —
Iso Temp Sense Out Of Bounds PCS2REXA_a103_IsoTempSenseOutOfBounds —
Iso Temp Sensor PCS2REXA_a103_IsoTempSensor —
Iso Temp Sensor Fall Time Out Of Bounds PCS2REXA_a103_IsoTempSensorFallTimeOutOfBounds —
Iso Temp Sensor MIA PCS2REXA_a103_IsoTempSensorMIA —
Iso Temp Sensor Rise Fall Mismatch PCS2REXA_a103_IsoTempSensorRiseFallMismatch —
Show 2 more fields
Signal Unit
Iso Temp Sensor Rise Time Out Of Bounds PCS2REXA_a103_IsoTempSensorRiseTimeOutOfBounds —
Rise Time Open Loop PCS2REXA_a103_RiseTimeOpenLoop nS

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PCS2REXA_a103.

Browse all PCS2REXA alert codes