PCS2REXA_a071 — Hv Batt Bot Sensor Irrational

Full alert identifier: PCS2REXA_a071_hvBattBotSensorIrrational

Alert description

The high voltage (HV) battery bottom voltage measurement is irrational

Potential impact

DCDC, AC charging, and AC outlet functionality may be limited or paused

Set condition

The HV battery bottom voltage is irrationally high or low

Clear condition

The HV battery bottom voltage measurement comes back within a rational sensor range

Signals to check

These diagnostic fields are associated with PCS2REXA_a071. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Hv Batt Bot Sensor Measurement PCS2REXA_a071_hvBattBotSensorMeasurement V
Hv Batt External Ref Value PCS2REXA_a071_hvBattExternalRefValue
2047
SNA
V

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PCS2REXA_a071.