PCS2REXA_a084 — Ac N Current Offset Irrational
Full alert identifier: PCS2REXA_a084_acNCurrentOffsetIrrational
Alert description
The AC Line N current has an irrationally high DC offset
Potential impact
AC charging and AC outlet functionality may be limited or paused
Set condition
The AC Line N current has an irrationally high DC offset
Clear condition
The DC offset falls back within normal bounds
Signals to check
These diagnostic fields are associated with PCS2REXA_a084. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Ac N Current Offset
PCS2REXA_
|
A |
Ac N Current RMS
PCS2REXA_
|
A |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PCS2REXA_a084.