PCS2REXA_a079 — Ac L2 N Voltage Offset Irrational
Full alert identifier: PCS2REXA_a079_acL2NVoltageOffsetIrrational
Alert description
The AC Line 2 to Neutral voltage has an irrationally high DC offset
Potential impact
AC charging and AC outlet functionality may be limited or paused
Set condition
The AC Line 2 to Neutral voltage has an irrationally high DC offset
Clear condition
The DC offset falls back within normal bounds
Signals to check
These diagnostic fields are associated with PCS2REXA_a079. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Ac L 2 N Voltage Offset
PCS2REXA_
|
V |
Ac L 2 N Voltage RMS
PCS2REXA_
|
V |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PCS2REXA_a079.