PCS2REXA_a077 — Lv Bus Volt Sensor Irrational
Full alert identifier: PCS2REXA_a077_lvBusVoltSensorIrrational
Alert description
The low voltage (LV) bus measurement is irrational
Potential impact
DCDC, AC charging, and AC outlet functionality may be limited or paused
Set condition
The LV bus voltage is irrationally high or low
Clear condition
The LV bus measurement comes back within a rational sensor range
Signals to check
These diagnostic fields are associated with PCS2REXA_a077. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Lv Bus External Ref Value
PCS2REXA_
|
V |
Lv Bus Voltage Measurement
PCS2REXA_
|
V |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PCS2REXA_a077.