HVREX_a745 — Soc Imbalance
Full alert identifier: HVREX_a745_SocImbalance
Alert description
The battery management system (BMS) detects a possible state of charge (SOC) imbalance.
Potential impact
Maximum SOC is reduced to 50%.
Set condition
The BMS detects that the difference between the most-charged brick and the least-charge brick in the high voltage (HV) pack is greater than the acceptable threshold.
Clear condition
The BMS has detected that the difference between the maximum brick voltage and the minimum brick voltage is below the acceptable threshold.
Signals to check
These diagnostic fields are associated with HVREX_a745. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Avg Brick Soc
HVREX_
|
% |
Max Brick Soc
HVREX_
|
% |
Max Brick Soc Id
HVREX_
|
— |
Min Brick Soc
HVREX_
|
% |
Min Brick Soc Id
HVREX_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of HVREX_a745.