HVREX_a732 — Cac Imbalance

Full alert identifier: HVREX_a732_CacImbalance

Alert description

The Calculated Amp-hour Capacity (CAC) difference of bricks within a module exceeds the acceptable threshold. This results in reduced battery performance and limits maximum range.

Potential impact

Reduced battery performance and reduced maximum range.

Set condition

The estimated imbalance between the average CAC and minimum CAC within a single module exceeds the imbalance threshold.

Clear condition

The estimated imbalance between the average CAC and minimum CAC within a single module is within the acceptable imbalance threshold.

Signals to check

These diagnostic fields are associated with HVREX_a732. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Avg Brick Cac HVREX_a732_avgBrickCac
8191
SNA
Ah
Min Brick Cac HVREX_a732_minBrickCac
8191
SNA
Ah
Min Brick Cac Id HVREX_a732_minBrickCacId
255
SNA
—
Mod Cac Imbalance Pct HVREX_a732_modCacImbalancePct %

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of HVREX_a732.

Browse all HVREX alert codes