The battery management system (BMS) has detected a high voltage sense harness (VSH) impedance.

Potential impact

Inability to charge, drive, or support the low voltage (LV) system

Set condition

The BMS detects a VSH impedance value above the threshold.

Clear condition

All bricks report VSH impedance values within the threshold.

Signals to check

These diagnostic fields are associated with HVREX_a742. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Brick ID HVREX_a742_brickID
255
SNA
—
Delta V HVREX_a742_deltaV V
Retry Count HVREX_a742_retryCount —