Skip to content

HVREX_a201 — Module Temp Sense Fault

Full alert identifier: HVREX_a201_ModuleTempSenseFault

Alert description

HVBATT detects that any module in the battery pack cannot measure temperature properly.

Potential impact

Inability to charge, drive, or support the low voltage (LV) system.

Set condition

A battery monitoring board (BMB) detects that all of the thermistors on a module are BAD or SNA.

Clear condition

HVBATT detects that all modules in the battery pack are sensing temperature nominally.

Signals to check

These diagnostic fields are associated with HVREX_a201. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Module 1 Temp Sense Fault HVREX_a201_module1TempSenseFault —
Module 2 Temp Sense Fault HVREX_a201_module2TempSenseFault —
Module 3 Temp Sense Fault HVREX_a201_module3TempSenseFault —
Module 4 Temp Sense Fault HVREX_a201_module4TempSenseFault —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of HVREX_a201.

Browse all HVREX alert codes