HVREX_a241 — Pack Voltage Mismatch Fault

Full alert identifier: HVREX_a241_PackVoltageMismatchFault

Alert description

HVBATT detects that the sum of brick voltages deviates from measured pack voltage.

Potential impact

Inability to charge, drive, or support the low voltage (LV) system

Set condition

HVBATT detects that the sum of brick voltages deviates from pack voltage by more than 5 percent.

Clear condition

HVBATT detects that the sum of brick voltages is within 5 percent of the measured pack voltage.

Signals to check

These diagnostic fields are associated with HVREX_a241. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Pack Voltage By Adc HVREX_a241_packVoltageByAdc V
Pack Voltage By Sum Of Bricks HVREX_a241_packVoltageBySumOfBricks V

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of HVREX_a241.