Skip to content

HVREX_a120 — External Isolation

Full alert identifier: HVREX_a120_ExternalIsolation

Alert description

The battery management system (BMS) detects that high voltage (HV) isolation is too low while pack contactors are closed.

Potential impact

Inability to charge, drive, or support the low voltage (LV) system

Set condition

The BMS has detects that HV isolation is below the warning threshold while contactors are closed.

Clear condition

The BMS has detects that HV isolation is within the acceptable threshold while contactors are closed.

Signals to check

These diagnostic fields are associated with HVREX_a120. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Iso Negative R HVREX_a120_isoNegativeR kOhm
Iso Positive R HVREX_a120_isoPositiveR kOhm

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of HVREX_a120.

Browse all HVREX alert codes