Skip to content

HVREX_a011 — Isolation

Full alert identifier: HVREX_a011_Isolation

Alert description

High voltage isolation is too low for the pack to be online

Potential impact

Pack may not come online

Set condition

Isolation is measured to be below the alert threshold while pack contactors are closed

Clear condition

Isolation is measured to be above the alert threshold

Signals to check

These diagnostic fields are associated with HVREX_a011. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Iso Resistance HVREX_a011_isoResistance kOhm
Mode HVREX_a011_mode
0
MODE RESET
1
VEHICLE ISOLATION MODE
2
FEIM NEGATIVE MODE
3
FEIM POSITIVE MODE
4
VOLTAGE SETTLING MODE
—

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of HVREX_a011.

Browse all HVREX alert codes