Skip to content

HVBATT_a742 — Vsh Failure

Full alert identifier: HVBATT_a742_VshFailure

Alert description

The battery management system (BMS) has detected a high voltage sense harness (VSH) impedance.

Potential impact

Inability to charge, drive, or support the low voltage (LV) system

Set condition

The BMS detects a VSH impedance value above the threshold.

Clear condition

All bricks report VSH impedance values within the threshold.

Signals to check

These diagnostic fields are associated with HVBATT_a742. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Brick ID HVBATT_a742_brickID
255
SNA
—
Delta V HVBATT_a742_deltaV V
Retry Count HVBATT_a742_retryCount —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of HVBATT_a742.

Browse all HVBATT alert codes