HVBATT_a290 — Acjb Gfci Self Test Failure

Full alert identifier: HVBATT_a290_AcjbGfciSelfTestFailure

Alert description

The Ground Fault Circuit Interrupter (GFCI) sensor on the AC Junction Box (ACJB) does not pass a self test.

Potential impact

AC Outlets may be unavailable.

Set condition

The GFCI sensor does not properly measure the injected self test current.

Clear condition

The GFCI sensor passes a self test.

Signals to check

These diagnostic fields are associated with HVBATT_a290. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Acjb Min Board Temperature HVBATT_a290_AcjbMinBoardTemperature C
Gfci Self Test Detected Current Rms HVBATT_a290_GfciSelfTestDetectedCurrentRms
4095
SNA
A

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of HVBATT_a290.