HVBATT_a740 — Bp1 Impedance Deviation
Full alert identifier: HVBATT_a740_Bp1ImpedanceDeviation
Alert description
High impedance was detected on one or more bricks.
Potential impact
One or more cells in a brick are likely missing, resulting in a high impedance current path. Other potential causes are a high Direct Current Resistance (DCR), intermittent anode laser weld on the given brick(s), or an islanded brick.
Set condition
Impedance for one or more bricks exceeds the noise threshold for several measurement counts.
Clear condition
All bricks have impedance measurements within the noise threshold.
Signals to check
These diagnostic fields are associated with HVBATT_a740. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Fault Threshold
HVBATT_
|
Ratio |
Max Brick Impedance
HVBATT_
|
mOhm |
Max Normalized Impedance Dev
HVBATT_
|
Ratio |
Num Bricks
HVBATT_
|
— |
Worst Brick ID
HVBATT_
|
— |
Worst Brick Soc
HVBATT_
|
PCT |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of HVBATT_a740.