Skip to content

HVBATT_a145 — Fc Pos Ctr Close Fail No Coil Current

Full alert identifier: HVBATT_a145_FcPosCtrCloseFailNoCoilCurrent

Alert description

Tried to close positive contactor but failed because the coil drive current was too low.

Potential impact

Positive FC contactor will remain open.

Set condition

Contactor state timed out of PULLED_IN because of insufficient contactor coil current.

Clear condition

Contactor state is ECONOMIZED.

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of HVBATT_a145.

Browse all HVBATT alert codes