Skip to content

HVBATT_a050 — Fc Ctr Close Fail No Voltage Match

Full alert identifier: HVBATT_a050_FcCtrCloseFailNoVoltageMatch

Alert description

Tried to close FC contactors but failed because a voltage match was not maintained.

Potential impact

FC contactors will remain open.

Set condition

Contactor control state exited CLOSING due to voltage match being lost.

Clear condition

Contactor control state is CLOSED.

Signals to check

These diagnostic fields are associated with HVBATT_a050. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Dc Link Voltage HVBATT_a050_dcLinkVoltage V
Fc Link Voltage HVBATT_a050_fcLinkVoltage V
Voltage Diff HVBATT_a050_voltageDiff V

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of HVBATT_a050.

Browse all HVBATT alert codes