HVBATT_a050 — Fc Ctr Close Fail No Voltage Match
Full alert identifier: HVBATT_a050_FcCtrCloseFailNoVoltageMatch
Alert description
Tried to close FC contactors but failed because a voltage match was not maintained.
Potential impact
FC contactors will remain open.
Set condition
Contactor control state exited CLOSING due to voltage match being lost.
Clear condition
Contactor control state is CLOSED.
Signals to check
These diagnostic fields are associated with HVBATT_a050. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Dc Link Voltage
HVBATT_
|
V |
Fc Link Voltage
HVBATT_
|
V |
Voltage Diff
HVBATT_
|
V |
Check other alerts