Skip to content

HVBATT_a049 — Pack Ctr Close Fail No Voltage Match

Full alert identifier: HVBATT_a049_PackCtrCloseFailNoVoltageMatch

Alert description

Tried to close pack contactors but failed because a voltage match was not maintained.

Potential impact

Pack contactors will remain open.

Set condition

Contactor control state exited CLOSING due to voltage match being lost.

Clear condition

Contactor control state is CLOSED.

Signals to check

These diagnostic fields are associated with HVBATT_a049. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Dc Link Voltage HVBATT_a049_dcLinkVoltage V
Pack Voltage HVBATT_a049_packVoltage V
Voltage Diff HVBATT_a049_voltageDiff V

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of HVBATT_a049.

Browse all HVBATT alert codes