Skip to content

HVBATT_a122 — Isolation Degradation

Full alert identifier: HVBATT_a122_IsolationDegradation

Alert description

The battery management system (BMS) detects that the high voltage (HV) isolation contactor closed below the warning threshold.

Potential impact

This alert indicates that HV isolation is low, but above the sufficient level for vehicle operation.

Set condition

The BMS detects that the HV isolation was below the warning threshold when pack contactors closed.

Clear condition

The BMS detects that HV isolation is above the warning threshold when pack contactors closed.

Signals to check

These diagnostic fields are associated with HVBATT_a122. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Isolation Resistance HVBATT_a122_isolationResistance kOhm
Mode HVBATT_a122_mode
0
MODE RESET
1
VEHICLE ISOLATION MODE
2
FEIM NEGATIVE MODE
3
FEIM POSITIVE MODE
4
VOLTAGE SETTLING MODE
—

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of HVBATT_a122.

Browse all HVBATT alert codes