Skip to content

HVBATT_a010 — Internal Isolation

Full alert identifier: HVBATT_a010_InternalIsolation

Alert description

Measurement of internal isolation (within the pack) is too low

Potential impact

Pack may not come online

Set condition

Internal isolation is measured to be below the alert threshold

Clear condition

Internal isolation is measured to be above the alert threshold

Signals to check

These diagnostic fields are associated with HVBATT_a010. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Iso Resistance HVBATT_a010_isoResistance kOhm
Pack Negative V HVBATT_a010_packNegativeV V
Pack Positive V HVBATT_a010_packPositiveV V

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of HVBATT_a010.

Browse all HVBATT alert codes