Skip to content

HVBATT_a080 — Bp2 Pack Over Temperature Warning

Full alert identifier: HVBATT_a080_Bp2PackOverTemperatureWarning

Alert description

A battery pack 2 module temperature is above the warning temperature limit

Potential impact

Power/drive limits may be reduced

Set condition

A battery pack 2 module temperature is above the warning temperature limit for X duration (in seconds)

Clear condition

All battery pack 2 module temperatures are below warning temperature limit

Signals to check

These diagnostic fields are associated with HVBATT_a080. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Sensor Id HVBATT_a080_sensorId —
Temperature HVBATT_a080_temperature C

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of HVBATT_a080.

Browse all HVBATT alert codes