HVBATT_a079 — Bp1 Pack Over Temperature Warning
Full alert identifier: HVBATT_a079_Bp1PackOverTemperatureWarning
Alert description
A battery pack 1 module temperature is above the warning temperature limit
Potential impact
Power/drive limits may be reduced
Set condition
A battery pack 1 module temperature is above the warning temperature limit for X duration (in seconds)
Clear condition
All battery pack 1 module temperatures are below warning temperature limit
Signals to check
These diagnostic fields are associated with HVBATT_a079. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Sensor Id
HVBATT_
|
— |
Temperature
HVBATT_
|
C |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of HVBATT_a079.