Skip to content

HVBATT_a017 — Hs Shunt Asic Cal Not Used

Full alert identifier: HVBATT_a017_HsShuntAsicCalNotUsed

Alert description

The programmed high side shunt application-specific integrated circuit (ASIC) calibration is not being used for high voltage (HV) current sensing. The default high side shunt ASIC gain will be used and current measurement accuracy may be reduced.

Potential impact

The default high side shunt ASIC gain will be used for high voltage (HV) current sensing. High side shunt current measurement accuracy may be reduced.

Set condition

The stored high side shunt ASIC gain is invalid or the written gain is outside the allowed tolerance.

Clear condition

The stored high side shunt ASIC gain is valid and the written gain is within the allowed tolerance.

Signals to check

These diagnostic fields are associated with HVBATT_a017. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Stored Asic Gain Pct HVBATT_a017_storedAsicGainPct
-8388608
SNA
percent
Stored Asic Gain Valid HVBATT_a017_storedAsicGainValid —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of HVBATT_a017.

Browse all HVBATT alert codes