HVBATT_a015 — Ls Shunt Bar Cal Not Used

Full alert identifier: HVBATT_a015_LsShuntBarCalNotUsed

Alert description

The programmed bar resistance calibration is not being used for high voltage (HV) current sensing. The default low side shunt bar resistance will be used and current measurement accuracy may be reduced.

Potential impact

The default low side shunt bar resistance will be used for high voltage (HV) current sensing. Low side shunt current measurement accuracy may be reduced.

Set condition

The stored low side shunt bar resistance is invalid or the written gain is outside the allowed tolerance.

Clear condition

The stored low side shunt bar resistance is valid and the written gain is within the allowed tolerance.

Signals to check

These diagnostic fields are associated with HVBATT_a015. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Stored Bar Resistance HVBATT_a015_storedBarResistance
32767
SNA
nOhms
Stored Bar Resistance Valid HVBATT_a015_storedBarResistanceValid —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of HVBATT_a015.

Browse all HVBATT alert codes